How Does the Pump Start and Stop in an Oil-Air Lubrication System?


Release time:

2024-02-10

The pump operation in an oil-air lubrication system is designed to be automatic and pressure-controlled, ensuring stable and efficient lubricant supply without continuous running.

Normal Start–Stop Operation
Once the system is powered on, the selected pump starts automatically. It delivers lubricant to the accumulator and all substations, building up system pressure.

  • When the pressure reaches approximately 70 bar, the pump stops.
  • As lubrication points consume oil, system pressure gradually decreases.
  • When the pressure drops to around 50 bar, the pump restarts and resumes oil supply.

This intermittent operation cycle (start–stop based on pressure thresholds) ensures consistent lubrication while reducing energy consumption and pump wear.

Fault Protection: When the Pump Stops
To protect the system and equipment, the pump will stop operating if any of the following faults occur:

  • Low Oil Level: When the reservoir level falls below the minimum limit
  • Progressive Distributor Failure: If the distributor cannot function or is blocked
  • Abnormal Compressed Air Pressure: When air pressure is too low or unstable

In these cases, the pump remains stopped until the fault is identified and resolved, preventing damage caused by improper lubrication.

Conclusion
This pressure-based automatic control ensures reliable lubricant delivery, energy efficiency, and system safety—making oil-air lubrication systems highly dependable in demanding industrial applications.