How to adjust an oil-air lubrication system to local mode?


Release time:

2025-09-03

When operating an oil-air lubrication system in local mode, several steps are required to ensure proper parameter configuration and stable system operation.

 

1. Set System Parameters

Before starting the system, the required parameters must be configured.

Tap the Parameter Settings button on the control interface and enter the password to confirm access. Then tap the Parameter Settings button again to enter the parameter configuration screen. In this interface, set the operating cycle and the number of strokes according to the system requirements.

 

2. Check System Operating Pressure

During system operation, verify that the compressed air pressure is maintained within 4–6 bar, while the oil pressure should remain within 50–70 bar. These pressure ranges ensure stable oil-air delivery throughout the lubrication system.

At the same time, inspect the transparent oil-air tubes of each substation to confirm that the oil-air flow is normal.

 

3. Adjust Protection and Temperature Settings

Adjust the motor protection switch so that the operating current is set to approximately 2 A.

In addition, set the oil temperature on the temperature control panel within the range of 25–35°C. During summer conditions, the heater can be switched off if heating is not required.

Proper commissioning in local mode helps ensure the stable operation, accurate lubrication delivery, and reliable performance of the oil-air lubrication system.